# Roadmap
|
|
|
|
This file tracks planned GoSentry work that is larger than a single bug fix.
|
|
Completed work is recorded in [CHANGELOG.md](CHANGELOG.md), not here.
|
|
|
|
## Open Items
|
|
|
|
### Per-job command timeout
|
|
|
|
`runner.RunJob` applies a fixed **30s** timeout to every command (`commandTimeout`
|
|
in `src/runner/runner.go`). Long-running or interactive scripts need a longer
|
|
limit; quick health checks may need a shorter one.
|
|
|
|
Add an optional per-job timeout (seconds) on `domain.Job`, with a global default
|
|
in `gosentry.json` for jobs that leave the field empty — the same inherit pattern
|
|
as `overlap_policy`. Wire the value through `RunJob`; expose it in the job dialog
|
|
and Settings; validate on save. `StartOnly` jobs should keep measuring launch
|
|
latency only and remain unaffected by the run timeout.
|
|
|
|
### Window size persistence *(frozen)*
|
|
|
|
Window size is currently **not** saved on quit or close. Saving was disabled
|
|
because `w.Canvas().Size()` returns the maximized dimensions when the window is
|
|
maximized, which would corrupt the stored size on the next launch.
|
|
|
|
Re-enabling requires a cross-platform way to detect the maximized state before
|
|
saving. Fyne v2.x has no API for this; it needs per-OS native calls:
|
|
`IsZoomed` (Windows), `_NET_WM_STATE` (X11/Linux), `NSWindow.isZoomed`
|
|
(macOS). Unfreeze once that detection is in place.
|
|
|
|
**Disadvantages of a platform-specific approach:**
|
|
|
|
- *Three separate implementations.* Windows, macOS, and Linux each need their
|
|
own file guarded by a build tag. Each adds CGO bindings or raw syscall
|
|
wrappers that must be kept in sync as OS APIs evolve.
|
|
- *Linux is not one target.* X11 and Wayland have completely different window
|
|
state models. `_NET_WM_STATE` is X11-only; under Wayland the compositor
|
|
controls window decorations and there is no stable client-side API to query
|
|
the maximized state. A single `linux` build tag cannot cover both correctly.
|
|
- *Native window handle is not exposed.* Fyne does not surface the underlying
|
|
`HWND` / `NSWindow` / `XID` through its public API. Obtaining it requires
|
|
either enumerating OS-level windows by PID (fragile, finds wrong windows when
|
|
dialogs are open) or reaching into Fyne/GLFW internals (breaks on Fyne
|
|
upgrades).
|
|
- *Thread-safety constraints.* Win32 and GLFW both require their calls to be
|
|
made from the OS main thread. Tray-menu callbacks run on a separate goroutine,
|
|
so any native call must be marshalled back to the main thread, adding
|
|
synchronisation complexity.
|
|
- *Test coverage gap.* Maximized-state detection cannot be exercised by Fyne's
|
|
headless test driver; it requires a real display and manual or screen-capture
|
|
automation per platform.
|
|
|
|
### History tab — column filters (Trigger / Job / State)
|
|
|
|
Add dropdown filters above the History table so the user can narrow rows by
|
|
trigger source, job name, or run state. Blocked on Fyne native support: the
|
|
current `widget.Table` has no built-in filter API, and a filter bar built from
|
|
`widget.Select` widgets above the table feels visually out-of-place. Revisit
|
|
when Fyne adds first-class column filtering or a composable data-grid widget.
|